結他/低音結他樂器無線套裝

XSW 1-Cl1

增強你的音樂吧!為樂器演奏者提供易於使用的一體式無線系統。
選擇產品變體

概述

放大你的音樂吧!選擇XS WIRLESS 1,能透過無線傳輸和多達10個兼容的頻道,穩定UHF頻段。XS WIRELESS 1 INSTRUMENT SET是一款令結他手及低音結他手易於使用的無線系統,非常適合現場演出。該套裝包括一個固定式接收器,能夠快速設置及簡易操作,以及簡約的腰包式發射器和堅固的儀器電線。


特性

  • 簡約的腰包發射器,堅固的儀器電線

  • 天線切換式分集接收

  • 集成天線

  • 通過遠讀波道自動進行頻率管理和同步,便於設置

  • 在大頻寬內可選UHF頻率

  • 多達10個兼容的頻道


包裝內含?

  • 1個接收器EM-XSW 1
  • 1個腰包式發射器SK-XSW
  • 1條儀器電線Cl1
  • 1個電源供應器NT 12-5 CW
  • 2枚AA電池

技術數據

  • 尺寸
    接收器:約200 x 42 x 127毫米
    腰包式發射器:約71 x 96 x 28毫米
  • THD,總諧波失真
    ≤ 0.9%
  • 重量
    約340克(米高峰),約95g(發射器)
  • 信噪比
    ≥ 103分貝
  • RF輸出功率
    10毫瓦
  • 交換帶寬
    高達24 MHz
  • 工作時間
    約10小時
  • 調製
    寬帶FM
  • 電源
    接收器:12 V DC nom。 / 300 mA
    發射器:2枚AA電池,1.5V
  • 輸出電壓
    1/4“(6.3 mm)插孔(不平衡):+ 6 dBu,XLR插孔(平衡):+12 dBu
  • 外殼
    堅固的ABS外殼
  • 頻率
    8個頻道庫,每個頻道庫最多有10個出廠預設頻道
  • 頻率範圍
    A:548-572MHz,GB:606-630MHz
    B: 614-638 MHz
    C: 766-790 MHz
    D: 794-806 MHz
    E: 821-832 MHz, 863-865 MHz
    K: 925-937.5 MHz
  • 靈敏度
    < 3 μV at 52 dB(A)rms S/N
  • 峰值偏差的聲壓級
    130分貝
  • 靜音
    從3dBμV至28dBμV皆可調(與導頻音結合)
  • 同步
    2.4 GHz,低功耗OQPSK(僅在同步期間有效)
  • 輸入靈敏度
    1.5毫伏/帕
  • 音频频率响应
    咪高峰:50至16,000 Hz(-3 dB)
  • Adjustment Range Transmitter
    0到-30 分貝,以10 分貝為單位作調整
  • Audio adjustment range
    45 分貝,以5 分貝為單位作調整
  • Line / Mic level
    20 分貝,可切換
  • Temperature Range
    操作:0°C至+ 40°C,儲存:-20°C至+ 70°C
  • Receiver Principle
    雙變頻超外差
  • 多樣化產品
    天線會通過內部天線以作切換分集

FAQ

  • How do I find a frequency (ie: perform a frequency scan)?

    To perform a frequency scan on the XS Wireless products follow these steps:

    1) Press the "UP" or "DOWN" button to scroll through the menu options on the receiver.

    2) Press the "SET" button to select the SCAN option. NOTE: The unit automatically selects the next available unused frequency. 

    Once the new frequency is selected on the receiver the transmitter needs to by synced to the receiver. To do this follow these steps:

    1) Press and hold the "SYNC" button on the transmitter until the "SYNC" symbol flashes on the receiver.

    2) Press the "SYNC" button on the receiver.

    NOTE: If a frequency SCAN is performed and no available frequencies are found then the SQUELCH setting will need to be increased. Once the SQUELCH setting has been increased repeat the steps of the frequency scan and then SYNC accordingly.



    XSW 1-Cl1-GB ( #506999 ), XSW 1-Cl1-C ( #506996 ), XSW 1-Cl1-K ( #507100 )
  • What adjustments can I do to improve sound quality?

    There are two settings that have the greatest effect on sound quality:

    MICROPHONE SENSITIVITY
    This is how sensitivity the microphone pick up is and this is adjusted on the microphone/body pack itself. Typically for general speaking the sensitivity should be set around -15 to -18 dB. You will need to adjust this depending on the exact application. Adjusting closer to 0 dB is will be more sensitive and further away from 0 dB is less sensitive. If the microphone is too sensitive the input will overload the microphone and the AF level will peak and the audio will be clipped.  It is suitable to adjust the level so that the AF peak indicator lights up only briefly during the loudest passages.

    AF OUTPUT
    This is how strong the signal is exiting out of the receiver into the sound board/speakers/etc. Typically this will be set to 0 dB or +6 dB if connected to equipment which is expecting a line level input . If you are connected to equipment expecting a mic level input you will typically need to drop this AF output down to -24 dB or -30 dB.  If your equipment has the option, it is best to try to run the equipment in line level mode.

    NOTE: If the AF Output is too high it may over load the input on any connected equipment (sound board/speakers/etc) and may create noise in the form of distortion/rumbling.



    XSW 1-Cl1-K ( #507100 )
  • Why is there no audio coming from the microphone?

    Not having audio coming from a microphone could be caused by a few different scenarios.
    Firstly check that the transmitter and receiver are both on the same frequency as this is key to the system working.
    Next check to make sure that the "MUTE" switch is not accidentally engaged (either fully or partially). The best way to do this is click the mute switch on and then back off.
    After checking the "MUTE" switch if no audio is present make sure that the microphone element is securely in place. If using a body pack transmitter make sure that the microphone or guitar cable is securely in place by disconnecting it and reconnecting it. NOTE: On the handheld microphone the capsule is locked into place and cannot come loose.
    If you are seeing RF and AF levels on the receiver but do not have any sound through your system it would be recommended to check the cables between the receiver and sound system, check the inputs on the sound system and check the AF out level on the receiver to ensure that it is set to the appropriate level for your sound system.



    XSW 1-Cl1-GB ( #506999 ), XSW 1-Cl1-C ( #506996 ), XSW 1-Cl1-K ( #507100 )

下載

  • Technical Data
    • Technical Data.pdf (4.4 MB) 下載

  • EC Declaration of Conformity
    • EU Declaration of Conformity XSW1_Series.pdf (1000 KB) 下載

  • 快速指南